Cellsite Routing

N2FE Flow Operation - Cellsite Routing

The CellsiteRouting selects an exit according to the value of the service key supplied in the initial DP.

The CellsiteRouting operation must have at least one cellsite exit configured.

Config Parameters

The CellsiteRouting operation config attributes are as follows.

Parameter Type Description
cellsites Array of
String
[Required] The cellsite Array is an Array of cellsite names. This Array must contain two or more Strings, the first String in the Array must be the `No match found` entry.

Example Operation

Here is an example CellsiteRouting operation in JSON representation.

    {
        "type": "CellsiteRouting",
        "id": "7",
        "base_node": "7",
        "exits": [ 1, 3, 6 ],
        "config": {
            "cellsites": ["No match found", "WLG", "MSTN"]
        }
    }

The index for each cellsite matches the index for their corrosponding exit in the exits Array.

In this example, calls from cellsite WLG will proceed down exit index 1 to operation ID 3, while calls from cellsite MSTN will proceed down exit index 2 to operation ID 6 and all other calls will exit down exit index 0 to operation ID 1.

Exits

The first exit is always the “No match found” exit.

Exit Index Name Description
`0` Exit #1 (No match found) [Required] All CellsiteRouting operations must have a no match exit.
1 Exit #1 [Required] All CellsiteRouting operations must have at least one cellsite exit configured.
2 Exit #3 + Additional exits may be present.